Porter — Porter
Porter Nitronox Plus
Demand-flow N2O/O2 analgesia system with adjustable 0-70% nitrous oxide, visual pressure gauges, and patient self-administration. Ideal for aesthetics and dermatology clinics.
Key Features
- Demand-flow delivery — gas only flows while the patient inhales
- Adjustable 0-70% nitrous oxide concentration
- Patient self-administration — patient controls the mouthpiece
- Visual pressure gauges for real-time cylinder and mixture indication
- Oxygen fail-safe — system cannot deliver N2O without O2
- O2 enrichment — increases oxygen percentage on shallow breathing
- Dual seal diaphragm block reduces leak risk
- Low inlet pressure alarm (~35 psi / 2.41 bar)
- Emergency air intake — patient can breathe room air if O2 is depleted
- Key lock prevents unauthorised use
- Pin-indexed cylinder regulators — no cross-connection
- Diameter-indexed gas hose connections — no cross-connection
- Rapid onset (~30 seconds) and fast recovery (5-10 minutes out of system)
- No driving restriction — most patients can drive home within 10 minutes of stopping
The Porter Nitronox Plus is a demand-flow nitrous oxide and oxygen system that delivers adjustable 0-70% N2O to the patient on inhalation. Unlike continuous-flow flowmeters, gas is only delivered while the patient is actively breathing through the mask — the patient retains control and can stop administration at any point. Visual pressure gauges provide real-time confirmation of cylinder supply and mixture. The system includes an oxygen fail-safe, dual seal diaphragm block, low inlet pressure alarm, emergency air-intake, key lock for unauthorised use, and a unique O2 enrichment feature that increases oxygen percentage if a repetitive shallow-breathing pattern is detected. Pin-indexed cylinder regulators and diameter-indexed hose connections prevent cross-connection. Onset of effect is typically 30 seconds and the gas clears the system within 5-10 minutes of stopping — patients can usually drive home 10 minutes after treatment.
Need advice? Speak to our specialist team.
Technical Specifications
- Type
- Demand-flow nitrous oxide & oxygen analgesia system
- N2O Range
- 0-70% (adjustable)
- Delivery Mode
- Demand flow (patient-triggered)
- Gas Compatibility
- N2O / O2
- Cylinder Connection
- Pin-indexed
- Hose Connection
- Diameter-indexed
- Pressure Gauges
- Visual (cylinder and mixture)
- Low Pressure Alarm
- ~35 psi (2.41 bar)
- Safety Features
- O2 fail-safe, dual seal diaphragm, low pressure alarm, emergency air intake, key lock, O2 enrichment
- Onset
- ~30 seconds
- Recovery
- 5-10 minutes out of system
- Fittings
- Pin-indexed regulators, diameter-indexed hoses